Plus15Filter - Plus 15 Respiratory Filter Escape Hood
U.S.-made Plus 15 is the clear choice for fire and smoke emergencies.
Please Note: Free Shipping does not apply
for this item. Please contact us for details.
Price: $ 108.50 / Each
U.S.-made Plus 15 is the clear choice for fire and smoke emergencies.
A high-quality, low-cost filtered escape hood that gives wearers a
life-saving 15 minutes of protection.
Tested to EN 403 certification
Protects against carbon monoxide
Clear FEP hood offers maximum visibility
5 1/2-year shelf life lowers replacement costs
Lightweight, portable, easy to use
One size fits most adults
Cost-effective solution for large groups or individuals
Dimensions: 6" X 5" X 4"
PLUS
15 Technical Manual
GENERAL INFORMATION: Intended
Use: The PLUS 15 is intended to be used as an escape filter hood in
fire and smoke emergencies where oxygen exists in sufficient quantity to
sustain life. Most fire situations contain sufficient oxygen. It is for a
single use only.
The PLUS 15 is not intended for chemical spills or
confined space situations where sufficient oxygen may not be available. In
these situations a self-contained breathing apparatus, such as an Essex
VRU should be considered.
All fire situations are unique, and so it
is impossible to predict exactly what toxic fumes will be given off. The
PLUS 15 has been designed in consideration of testing done by recognized
international regulatory agencies that have studied fires. The
contaminates that the PLUS 15 will remove, are based on these
international studies. However, it is not possible to guarantee that the
PLUS 15 will remove all of the contaminates from any particular
fire.
Duration of Use: The PLUS 15 will provide 15 minutes
of protection against exposure to toxic gases. Longer time durations can
be achieved against less severe environments. (Reference the Challenge
Atmosphere Section of this Technical Data Package)
Size: 7
in long x 4 in tall x 5 in wide when packaged in its protective nylon
pouch
Weight: Approx. 450 grams, individual weight varies,
specific weight is listed on the foil barrier
pouch.
Packaging: The PLUS 15 is folded inside a
hermetically sealed, waterproof barrier pouch, which is then packaged
inside a protective nylon pouch. The barrier pouch can be opened by hand
and requires no additional tools.
Shelf Life: The PLUS 15
has a shelf life of 5 years and 6 months from date of manufacture as long
as the hermetically sealed barrier pouch has not been damaged and unit is
properly stored in its nylon pouch.
Essex PB&R Corporation • Technical Data
Package for the PLUS 15 Respirator
Size and Fit: The PLUS 15 comes in only one size. Though the
unit is designed to be one-size fits most, leakage may occur due to
variables such as unique facial characteristics, facial hair, facial
piercing, etc.
Breathing Resistance: The breathing
resistance for inhalation is 3.2 in of H2O maximum and
exhalation is 1.2 in of H2O maximum.
Visibility:
The PLUS 15 offers a large field of visibility, with the use of clear FEP
material for the hood.
Protection Factor: The PLUS 15
provides an average protection factor of 50 inside of the nose cup. The
air being breathed inside the PLUS 15 is on average 50 times cleaner than
the air outside of the hood.
Verbal Communication: Though
the nose cup may muffle communication the PLUS 15 still allows for
communication without removing the hood or mask.
Oxygen: The
PLUS 15 does not provide oxygen. The contaminated air is drawn through the
filter, cleaned and delivered to the user. Do not use the PLUS 15 in an
oxygen deficient atmosphere.
Carbon Dioxide: Carbon Dioxide
is introduced into the hood by the reaction of the carbon monoxide filter
and by the breath exhaled by the user. Carbon Dioxide is removed from the
hood when the user exhales, opening the exhalation valve adjacent to the
filter and emitting air from inside the breathing zone.
Carbon
Monoxide: Carbon Monoxide (CO) is a toxic gas found in almost all
fires. It is the byproduct of incomplete combustion. The Plus 15 protects
against CO concentrations as high as 10,000 ppm for over 15
minutes.
Storage and Maintenance: The PLUS 15 may
be stored at temperatures between 85°C (185°F) and -30°C (-20°F). The only
maintenance needed for the PLUS 15 is to inspect the barrier pouch for any
tears, punctures, and loss of vacuum or gain in weight. If there is any
damage to the barrier pouch or the pouch has lost vacuum or the unit is
otherwise damaged DO NOT USE THE DEVICE.
CONSTRUCTION:
Hood Materials:
Hood:
FEP+ film
Neck Seal:
Elastic draw chord with synch ball
Head Harness:
Urethane Coated Rip Stop
Harness Straps:
Flame Retardant Coated Nylon
Nose Cup:
FDA Grade Silicone
Filter Materials:
Filter Holder:
Polycarbonate
Particulate Screen:
Pleated N95 filter
Acid Gas Pack:
Granular Activated Carbon
Carbon Monoxide Removal:
Granular CO Catalyst
Ordering Information:
Part Number
Description
MR-10015N
Essex PB&R PLUS 15 Air Purifying Escape Respirator w/
Soft Pouch
MR-10016N
Essex PB&R PLUS 15 Trainer
The Last Chance Rescue Filter Assembly has been
tested against the following toxic gases:
Challenge Gas
Concentration
Allowable Breakthrough
IDLH Levels
Actual Breakthrough
Carbon Monoxide*
2,500 ppm
200 ppm**
1200 ppm
<200 ppm** (24 min)
Carbon Monoxide*
10,000 ppm
200 ppm **
1200 ppm
<200 ppm** (24 min)
Hydrogen Cyanide
400 ppm
10 ppm
50 ppm
<10 ppm (60 min)
Hydrogen Chloride
1000 ppm
5 ppm
50 ppm
<5 ppm (170 min)
Hydrogen Sulfide
1000 ppm
10ppm
100 ppm
<10 ppm (390 min)
Sulfur Dioxide
100 ppm
3 ppm
100 ppm
<3 ppm (180 Min)
Acrolein (Propenal)
100 ppm
.5 ppm
5 ppm
<0.5 ppm (30 min)
Plus 15 test data conducted at AT Labs, a unit of Assay Technologies,
Pleasanton, CA Hydrogen Sulfide Test performed at AJE Testing and
Research, Boalsburg, PA Gas Conditions: Air Flow: 30 lpm Constant
Flow/ Temperature 208ºC/ Relative Humidity: 70% * Gas Conditions: Air
Flow: 30 lpm Constant Flow/258ºC/ Relative Humidity: 90% ** Time
Weighted Average
Please Contact Be Safe Plus LLC for more
information about Plus 15 Respiratory Filter Protection-
sales@besafeplus.com
973-928-2907
- Large Orders Welcome- Call for pricing